Carlos Palomino
WhatsApp →

[ Internal components · 5 min read ]

70 A coupling relay burnt inside the Elektroblock

The 70 A relay that connects the starter battery with the auxiliary one during driving charging is the component that fails most often in Schaudt Elektroblock units. It buzzes, sticks or stays open: three symptoms, one culprit. Here's when to replace it and how much it costs.

By Carlos Palomino · Elektroblock Workshop·
Song Chuan 897-1AH-C1 70 A relay inside a Schaudt Elektroblock EBL — battery coupling component
Real workshop photo · affected models: EBL 99 · EBL 99-G · EBL 220-2 · EBL 269 · EBL 267

What this relay does

The Song Chuan 897-1AH-C1 is a sealed power relay with 12 V DC coil and 70 A contacts rated at 14 V DC. Inside the Elektroblock it serves one purpose: when the engine runs and the alternator D+ signal is high, it energises and physically connects the starter battery with the auxiliary one so both charge in parallel from the alternator.

When the engine stops and the D+ signal drops, the relay opens and the two batteries decouple. This prevents the living area from draining the starter battery.

The three failure modes

1. Buzzing coil. The relay vibrates at mains frequency when energised. The coil has partial shorted turns and can no longer hold the armature steady. Audible as a continuous metallic buzz coming from the EBL when the engine runs. Charging still happens (sometimes) but relay life is seconds away.

2. Stuck contacts. The 70 A contacts have welded together from an inrush spike. The relay stays closed even with the engine off, which means the living area drains the starter battery overnight. Diagnosis: with the engine off and the key out, measure continuity between starter and auxiliary battery positives — if there’s continuity, the relay is stuck closed.

3. Open contacts. The contacts have burnt and no longer close reliably. The auxiliary doesn’t charge while driving but charges normally on 230 V mains. The coil may energise correctly but the mechanical connection fails.

How to test it with a multimeter

With the EBL removed and the capacitors discharged safely:

  • Coil resistance: between the two coil terminals, in ohms. Expected: 70-90 Ω. Zero or infinite = coil failure.
  • Contact resistance (relay energised with external 12 V on the coil): between the two power terminals, in diode mode. Expected: close to 0 Ω. Several ohms = burnt contacts.

Replacement

The relay is through-hole mounted on the EBL’s power board. Component cost is around €15-€20. Board-level replacement needs a temperature-controlled soldering iron (minimum 40 W) and solder-wick for the four or five large pins.

Workshop repair including part, labour, 24-hour bench test and warranty: €90-€120.

Next step

Time to repair? Free diagnosis by WhatsApp.

Send me the exact Elektroblock model and a photo of the LT panel. I'll confirm whether it's a common fault, the indicative price and how to pack it.

Message on WhatsApp